+380 (67) 577 67 75
Order a consultation
RU EN UK

Stationary high-voltage stand SVS-100

Delivery time 45
Order consultation
appointment
Specifications
Equipment

Power supply - single-phase AC network with voltage of 220 В20 V, frequency of 502 Hz

Power consumption, no more, VA, - ……………………………………………… ..500

Number of high voltage sources - …………………………………………… .3

Source parameters are given in the table

Parameter

Source type

BVI-50M-1

BVI-50M-2

BVI-1

The highest output alternating voltage, kV

50

50

1

 

 

 

 

The highest output current, mA

 

24 (when tested in Gloves and Bots mode)

10 (when tested in 3kV mode)

5 (when tested in 100kV mode)

-

ten

Overall dimensions, mm

290х315х675

290х315х675

Built in control unit

Weight, kg

35

35

 

 

Test bath parameters:

  • number of test electrodes ....... ……………………………………………… ..4

  • overall dimensions (with a stand), mm, …………………………………… .... 670х470х1120

  • dry weight, kg, not more than ......................................................................... 10

The reduced measurement error of the built-in meter

voltage,%, not more …………………………………………………………………………… ..3

The reduced measurement error of the built-in meter

current,%, not more ………………………………………………………………………………… ... 3

Parameters of high-potential current meter ITVR-4:

  • measurement limit (alternating current), mA, …………………………………………… ... 10

  • reduced relative measurement error,%, not more ………………………… 3

The area occupied by the device (recommended), m2, ……………………………………… ... 4

Equipment weight, kg, no more, …………………………………………………………… 100

Service life of the apparatus equipment …………………………………………………… 10 years

No.

Name

Qty.

Note

1

Control block

1

 

2

High-voltage test unit BVI-50 -1

1

Main unit

3

High-voltage test unit BVI-50 -2

1

For 100 kV tests

4

High-potential current meter ITVR-4

1

 

five

Battery charger ITVR-4

1

 

6

Signal lamp red

1

 

7

Interlock switch

1

 

8

Test bath for insulating bot and gloves included (stand, water tank, pump, filling gun, hoses)

1

 

9

Set of wires and cables for testing

1

 

10

High-voltage stationary stand SVS-100.
Manual. SVS-100 / 00.00.00.00RE

1

 

11

High-voltage stationary stand SVS-100.
The passport. SVS-100 / 00.00.00.00PS

1

 

Stationary high-voltage stand SVS-100 (hereinafter - the "stand") is intended for testing the insulation of protective equipment (insulating rods, rubber boots, gloves, power tools, etc.), insulation of power cables and solid dielectrics with variable high voltage of industrial frequency, regulated within 0 - 100kV.
The stand is designed for operation under a canopy or indoors at operating air temperatures from plus 5 ° C to plus 40 ° C, relative humidity 80% at a temperature of plus 20 ° C and atmospheric pressure 84.0 - 106.7 kPa (630 - 800 mmHg.).
To work with the stand, two operators are required who have permission to work with electrical installations with voltages above 1000 V.