Stationary high-voltage stand SVS-100
Power supply - single-phase AC network with voltage of 220 В20 V, frequency of 502 Hz
Power consumption, no more, VA, - ……………………………………………… ..500
Number of high voltage sources - …………………………………………… .3
Source parameters are given in the table
Parameter |
Source type |
||
BVI-50M-1 |
BVI-50M-2 |
BVI-1 |
|
The highest output alternating voltage, kV |
50 |
50 |
1 |
|
|
|
|
The highest output current, mA
|
24 (when tested in Gloves and Bots mode) 10 (when tested in 3kV mode) 5 (when tested in 100kV mode) |
- |
ten |
Overall dimensions, mm |
290х315х675 |
290х315х675 |
Built in control unit |
Weight, kg |
35 |
35 |
|
Test bath parameters:
-
number of test electrodes ....... ……………………………………………… ..4
-
overall dimensions (with a stand), mm, …………………………………… .... 670х470х1120
-
dry weight, kg, not more than ......................................................................... 10
The reduced measurement error of the built-in meter
voltage,%, not more …………………………………………………………………………… ..3
The reduced measurement error of the built-in meter
current,%, not more ………………………………………………………………………………… ... 3
Parameters of high-potential current meter ITVR-4:
-
measurement limit (alternating current), mA, …………………………………………… ... 10
-
reduced relative measurement error,%, not more ………………………… 3
The area occupied by the device (recommended), m2, ……………………………………… ... 4
Equipment weight, kg, no more, …………………………………………………………… 100
Service life of the apparatus equipment …………………………………………………… 10 years
No. |
Name |
Qty. |
Note |
1 |
Control block |
1 |
|
2 |
High-voltage test unit BVI-50 -1 |
1 |
Main unit |
3 |
High-voltage test unit BVI-50 -2 |
1 |
For 100 kV tests |
4 |
High-potential current meter ITVR-4 |
1 |
|
five |
Battery charger ITVR-4 |
1 |
|
6 |
Signal lamp red |
1 |
|
7 |
Interlock switch |
1 |
|
8 |
Test bath for insulating bot and gloves included (stand, water tank, pump, filling gun, hoses) |
1 |
|
9 |
Set of wires and cables for testing |
1 |
|
10 |
High-voltage stationary stand SVS-100. |
1 |
|
11 |
High-voltage stationary stand SVS-100. |
1 |
|
The stand is designed for operation under a canopy or indoors at operating air temperatures from plus 5 ° C to plus 40 ° C, relative humidity 80% at a temperature of plus 20 ° C and atmospheric pressure 84.0 - 106.7 kPa (630 - 800 mmHg.).
To work with the stand, two operators are required who have permission to work with electrical installations with voltages above 1000 V.