STATIONARY HIGH-VOLTAGE STAND SVS-50
Power supply - single-phase AC network with a voltage of 220-20 V, a frequency of 50-2 Hz
Power consumption, no more, VA, - ……………………………………………… 500
Number of high voltage sources - …………………………………………… .2
Parameter |
Source type |
|
BVI-50 |
BVI-1 |
|
The highest output alternating voltage, kV |
50 |
1 |
|
|
|
The highest output current, mA
|
26 (when tested in Gloves and Bots mode) 10 (when tested in 3kV mode) 10 (when tested in 50kV mode) |
ten |
Overall dimensions, mm |
290х315х675 |
Built in control unit |
Weight, kg |
35 |
|
Test bath parameters:
-
number of test electrodes ....... ……………………………………………… ..4
-
overall dimensions (with a stand), mm, ………………………………… .... 670х470х1120
-
dry weight, kg, no more than …………………………………………………… .10
The reduced measurement error of the built-in meter
voltage,%, not more than ………………………………………………………………………… ..3
The reduced measurement error of the built-in meter
current,%, not more ………………………………………………………………………………… ... 3
Parameters of high-potential current meter ITVR-4:
-
measurement limit (alternating current), mA, …………………………………………… ... 10
-
reduced relative measurement error,%, not more than ………………………… 3
The area occupied by the device (recommended), m2, ……………………………………… ... 4
Equipment weight, kg, no more, …………………………………………………………… 100
Service life of the apparatus equipment …………………………………………………… 10 years
No. |
Name |
Qty. |
Note |
1 |
Control block |
1 |
|
2 |
High-voltage test unit BVI-50 |
1 |
Main unit |
3 |
High-potential current meter ITVR-4 |
|
|
4 |
Battery charger ITVR-4 |
1 |
|
5 |
Signal lamp red |
1 |
|
6 |
Interlocking switch |
1 |
|
7 |
Test bath for insulating bot and gloves included (stand, water tank, pump, filling gun, hoses) |
1 |
|
8 |
Set of wires and cables for testing |
1 |
|
9 |
High-voltage stationary stand SVS-50. |
1 |
|
10 |
High-voltage stationary stand SVS-50. |
1 |
|
Stationary high-voltage stand SVS-50 (hereinafter referred to as the "stand") is intended for testing the insulation of protective equipment (insulating rods, rubber boots, gloves, power tools, etc.), power cables and solid dielectrics with variable high voltage of industrial frequency, regulated in within 0 - 50kV.
The stand is designed for operation under a canopy or indoors at operating air temperatures from plus 5 ° C to plus 40 ° C, relative humidity 80% at a temperature of plus 20 ° C and atmospheric pressure 84.0 - 106.7 kPa (630 - 800 mmHg.).
To work with the device, two operators are required who have permission to work with electrical installations with voltages above 1000 V.