+380 (67) 577 67 75
Order a consultation
HIGH-VOLTAGE TEST APPARATUS AV-50 / 70-2
Delivery time 45 days
Order consultation
Equipment in this category:
- KAEL-5 MOBILE CABLE ELECTROLABORATORY
- HIGH-VOLTAGE TEST APPARATUS AV-50 / 70-2
- KAELP-35 CABLE MOBILE ELECTRIC LABORATORY
- HIGH-VOLTAGE TEST APPARATUS AV-50 / 70-3
- COMBINED ELECTROTECHNICAL MOBILE LABORATORY ETL-35K
- HIGH-VOLTAGE APPARATUS AV-45-01
- INSTALLATION FOR TESTING OIL UIM-90
- ELECTROTECHNICAL MOBILE LABORATORY ETL-35T
- HIGH-VOLTAGE TEST STAND SVI-100
- HIGH-VOLTAGE TEST APPARATUS AV-50/70
- HIGH-VOLTAGE TEST APPARATUS AV-20-01
- High-voltage apparatus AV-60-01
- HIGH-VOLTAGE TEST APPARATUS AV-70-01
- UNIVERSAL BREAKDOWN INSTALLATION UPU-6
- HIGH-VOLTAGE TRANSFORMER IOM-100/20
- UNIVERSAL BREAKDOWN INSTALLATION UPU-10
- INSTALLATION FOR TESTING INSULATION WITH RECTIFIED VOLTAGE IM-65
Power supply - single-phase AC network with voltage 220 ± 20 V, frequency 50 ± 2 Hz
Power consumption, no more, VA, 2000
Number of high voltage sources 4
Source parameters are given in the table
Parameter
|
Source type
|
||
BVI-50
|
BVI-20
|
BVI-1
|
|
The highest output alternating voltage, kV
|
50
|
20
|
1
|
The highest output DC voltage, kV
|
70
|
-
|
-
|
The highest output current, mA
|
25
|
25
|
25
|
Overall dimensions, mm
|
270x295x660
|
270x295x660
|
225x160x195
|
Weight, kg
|
35
|
35
|
3
|
Test bath parameters:
- number of test electrodes 4
- overall dimensions (with stand), mm, 670х470х1120
- dry weight, kg, no more than 10
Built-in kilovoltmeter parameters:
- AC voltage measurement limits, kV, 1.20, 50
- reduced relative measurement error,%, no more than 3
Built-in current meter parameters:
- measurement limit (DC and AC), mA, 25
- reduced relative measurement error,%, no more than 3
Parameters of high-potential current meter ITVR-4:
- measurement limit (DC and AC), mA, 10
- reduced relative measurement error,%, no more than 3
The area occupied by the device (recommended), m2, 4
Equipment weight, kg, no more than 100
The service life of the apparatus of the apparatus is 10 years
No.
|
Name
|
Qty.
|
1
|
Control block
|
1
|
2
|
High-voltage test unit BVI-50
|
1
|
3
|
High-voltage test unit BVI-20
|
1
|
4
|
High-voltage test unit BVI-1
|
1
|
five
|
High-potential current meter ITVR-4
|
1
|
6
|
Battery charger ITVR-4
|
1
|
7
|
Signal lamp red
|
1
|
8
|
Interlocking switch
|
1
|
nine
|
Test bath for insulating bot and gloves included (stand, water tank, pump, filling gun, hoses)
|
1
|
ten
|
Measuring cell for testing liquid dielectrics complete with gauge template and cell mounting brackets.
|
1
|
eleven
|
Set of wires and cables for testing
|
1
|
12
|
X6 connector plug (door lock)
|
1
|
13
|
High-voltage apparatus AV-50 / 70-2.
Manual. AV-50 / 70-2 / 00.00.00.00RE |
1
|
fourteen
|
High-voltage apparatus AV-50 / 70-2.
The passport. AV-50 / 70-2 / 00.00.00.00PS |
1
|
High-voltage testing apparatus AV-50 / 70-2 (hereinafter - "apparatus") is intended for:
- testing of insulation of protective equipment (rubber boots, gloves, power tools, etc.) with alternating high voltage of industrial frequency, adjustable within 0 - 50 kV.
- testing the insulation of power cables and solid dielectrics with a rectified electric voltage up to 60 kV, as well as for testing solid dielectrics with a sinusoidal electric voltage of 50 Hz.
- determination of the breakdown voltage of liquid dielectrics with a voltage of 50 Hz up to 50 kV. (according to GOST 6581-75)
- Measurement of leakage currents of tested objects (protective equipment, arresters, etc.)
The device is designed for operation under a canopy or indoors at operating air temperatures from minus 10 ° C to plus 40 ° C, relative humidity 80% at a temperature of plus 20 ° C and atmospheric pressure 84.0 - 106.7 kPa (630 - 800 mmHg.).
The device can be used in two versions:
- stationary,
- figurative.
To work with the device, two operators are required who have permission to work with electrical installations with voltages above 1000 V.