+380 (67) 577 67 75
Order a consultation
UNIVERSAL BREAKDOWN INSTALLATION UPU-6
Equipment in this category:
- KAEL-5 MOBILE CABLE ELECTROLABORATORY
- HIGH-VOLTAGE TEST APPARATUS AV-50 / 70-2
- KAELP-35 CABLE MOBILE ELECTRIC LABORATORY
- HIGH-VOLTAGE TEST APPARATUS AV-50 / 70-3
- COMBINED ELECTROTECHNICAL MOBILE LABORATORY ETL-35K
- HIGH-VOLTAGE APPARATUS AV-45-01
- INSTALLATION FOR TESTING OIL UIM-90
- ELECTROTECHNICAL MOBILE LABORATORY ETL-35T
- HIGH-VOLTAGE TEST STAND SVI-100
- HIGH-VOLTAGE TEST APPARATUS AV-50/70
- HIGH-VOLTAGE TEST APPARATUS AV-20-01
- High-voltage apparatus AV-60-01
- HIGH-VOLTAGE TEST APPARATUS AV-70-01
- UNIVERSAL BREAKDOWN INSTALLATION UPU-6
- HIGH-VOLTAGE TRANSFORMER IOM-100/20
- UNIVERSAL BREAKDOWN INSTALLATION UPU-10
- INSTALLATION FOR TESTING INSULATION WITH RECTIFIED VOLTAGE IM-65
Output voltage setting limits, kV, | 1; 3; 6 |
Reduced relative error of setting and measuring the output voltage,%, no more | 3 |
Maximum output current, mA, | one hundred |
Reduced current measurement error,%, no more | 3 |
Threshold of current protection actuation, mA, | 72 ± 2 |
Power consumption, VA, no more | 650 |
Overall dimensions, mm, | 480x200x350 |
Weight, kg, not more, | 25 |
Operating time in continuous mode at maximum power, hour, | 8 |
Average product service life, years | 6 |
NOTE. The kilovoltmeter of the installation measures on an alternating voltage - the rms value, on a rectified voltage - the amplitude value of the voltage.
An AC milliammeter measures the rms value, at the rectified average (rectified average) current value.
Name
|
Qty.
|
Universal breakdown installation UPU-6.
|
1
|
Network wire.
|
1
|
High-voltage connecting wire.
|
1
|
Ground wire.
|
1
|
Universal breakdown installation UPU-6. Manual. UPU-6 / 00.00.00.00RE.
|
1
|
Universal breakdown installation UPU-6.
Passport UPU-6 / 00.00.00.00RE.
|
1
|
- Universal breakdown installation UPU-6 (hereinafter referred to as UPU-6) is intended for testing the insulation of electrical equipment and materials with alternating sinusoidal voltage with a frequency of 50 Hz and rectified voltage of negative polarity, adjustable within 0-6 kV with an output current of up to 100 mA at GOST6433.3-71
The field of application is electrical engineering and power engineering.
Due to the increased output current, the installation can be used for testing the insulation of large electrical machines at alternating voltage. It can be successfully used for testing protective equipment for appropriate voltages (gloves, etc.), as well as for charging capacitive energy storage devices.
- The unit is designed for operation indoors or under a canopy at operating air temperatures from plus 5 ° C to plus 40 ° C, relative humidity up to 80% at a temperature of plus 20 ° C and atmospheric pressure 84.0 - 106.7 kPa (630 - 800 mm Hg).
- Power supply - single-phase sinusoidal alternating current network with a voltage of 220 ± 20 V, a frequency of 50 ± 1 Hz.
- The installation is serviced by one operator with the right to work on installations with voltages above 1000V.