+380 (67) 577 67 75
Order a consultation
HIGH-VOLTAGE TEST APPARATUS AV-50/70
Delivery time 15 working days
Order consultation
Equipment in this category:
- KAEL-5 MOBILE CABLE ELECTROLABORATORY
- HIGH-VOLTAGE TEST APPARATUS AV-50 / 70-2
- KAELP-35 CABLE MOBILE ELECTRIC LABORATORY
- HIGH-VOLTAGE TEST APPARATUS AV-50 / 70-3
- COMBINED ELECTROTECHNICAL MOBILE LABORATORY ETL-35K
- HIGH-VOLTAGE APPARATUS AV-45-01
- INSTALLATION FOR TESTING OIL UIM-90
- ELECTROTECHNICAL MOBILE LABORATORY ETL-35T
- HIGH-VOLTAGE TEST STAND SVI-100
- HIGH-VOLTAGE TEST APPARATUS AV-50/70
- HIGH-VOLTAGE TEST APPARATUS AV-20-01
- High-voltage apparatus AV-60-01
- HIGH-VOLTAGE TEST APPARATUS AV-70-01
- UNIVERSAL BREAKDOWN INSTALLATION UPU-6
- HIGH-VOLTAGE TRANSFORMER IOM-100/20
- UNIVERSAL BREAKDOWN INSTALLATION UPU-10
- INSTALLATION FOR TESTING INSULATION WITH RECTIFIED VOLTAGE IM-65
2.1. Single-phase supply voltage
alternating current, V, - 220 ± 10%
2.2. Parameters of the device at rectified voltage in continuous mode (up to 5 minutes) at the nominal voltage in the network:
- the highest test voltage, kV, - 70;
- maximum measured current, mA, - 30
2.3. Parameters of the apparatus on alternating voltage in continuous mode (up to 5 minutes) at the rated value of the voltage in the network:
- the highest test voltage (effective value), kV, - 50;
- the highest measured current (effective value), mA, - 40
2.4. Power consumption, kVA, no more - 2.0
2.5. Reduced error of output voltage and current measurement,%, not more - 3.0
2.6. Weight, kg, no more:
control unit - 15
high voltage unit - 35
2.7. Dimensions:
control unit - 320x200x355
high voltage unit - 270x295x660
2.8. Average service life - 10 years
Name
|
Designation
|
Qty.
|
1. B 1. Control unit
|
|
1
|
2. B 2. High voltage unit
|
|
1
|
3. To 3. Network cable
|
|
1
|
4. П 4. Ground wire
|
|
2
|
5. P 5. High-voltage wire
|
|
1
|
6. Current-limiting resistor (ordered separately)
|
|
1
|
Operational documents
|
|
|
Hand Operation Manual
|
AV-50 / 70.00.00.00 RE
|
1
|
High-voltage testing apparatus AV-50/70 (hereinafter referred to as the apparatus) is intended for testing the insulation of power cables and solid dielectrics with rectified electric voltage, for testing solid dielectrics with a sinusoidal electric voltage of 50 Hz. The device allows performing, in a short-term mode, preliminary burning of the cable using a current-limiting resistor (to be specified in the order). In this version, the device has the letter "P" in its name.
The device can be used as a source of high voltage in test complexes when testing: cables with XLPE insulation with a frequency of 0.1 Hz; when testing electrical protective equipment.
The device is designed for operation under a canopy or indoors at operating air temperatures from minus 10 ° C to plus 40 ° C, relative humidity 80% at a temperature of plus 20 ° C and atmospheric pressure 84.0 - 106.7 kPa (630 - 800 mmHg.).